Filtered by vendor Gallagher
Subscriptions
Total
57 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-41402 | 1 Gallagher | 1 Command Centre | 2025-10-27 | 5.5 Medium |
| Client-Side Enforcement of Server-Side Security (CWE-602) in the Command Centre Server allows a privileged operator to enter invalid competency data, bypassing expiry checks. This issue affects Command Centre Server: 9.30 prior to vEL9.30.2482 (MR2), 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), all versions of 9.00 and prior. | ||||
| CVE-2025-35981 | 1 Gallagher | 1 Command Centre | 2025-10-27 | 5.5 Medium |
| Exposure of Private Personal Information to an Unauthorized Actor (CWE-359) in the Command Centre Server allows a privileged Operator to view limited personal data about a Cardholder they would not normally have permissions to view. This issue affects Command Centre Server: 9.30.1874 (MR1), 9.20.2337 (MR3), 9.10.3194 (MR6). | ||||
| CVE-2025-48428 | 1 Gallagher | 1 Command Centre | 2025-10-27 | 6.7 Medium |
| Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site. This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. | ||||
| CVE-2025-47699 | 1 Gallagher | 1 Command Centre | 2025-10-27 | 9.9 Critical |
| Exposure of Sensitive System Information to an Unauthorized Control Sphere (CWE-497) in the Gallagher Morpho integration could allow an authenticated operator with limited site permissions to make critical changes to local Morpho devices. This issue affects Command Centre Server: 9.30 prior to vEL9.30.2482 (MR2), 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. | ||||
| CVE-2025-48430 | 1 Gallagher | 1 Command Centre | 2025-10-27 | 5.5 Medium |
| Uncaught Exception (CWE-248) in the Command Centre Server allows an Authorized and Privileged Operator to crash the Command Centre Server at will. This issue affects Command Centre Server: 9.30 prior to vEL9.30.2482 (MR2), 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. | ||||
| CVE-2024-41146 | 1 Gallagher | 2 Controller 6000, Controller 7000 | 2025-07-21 | 4.6 Medium |
| Use of Multiple Resources with Duplicate Identifier (CWE-694) in the Controller 6000 and Controller 7000 Platforms could allow an attacker with physical access to HBUS communication cabling to perform a Denial-of-Service attack against HBUS connected devices, require a device reboot to resolve. This issue affects: Controller 6000 and Controller 7000 firmware versions 9.10 prior to vCR9.10.241108a (distributed in 9.10.2149 (MR4)), 9.00 prior to vCR9.00.241108a (distributed in 9.00.2374 (MR5)), 8.90 prior to vCR8.90.241107a (distributed in 8.90.2356 (MR6)), all versions of 8.80 and prior. | ||||
| CVE-2024-23194 | 1 Gallagher | 1 Command Centre | 2025-07-13 | 3.3 Low |
| Improper output Neutralization for Logs (CWE-117) in the Command Centre API Diagnostics Endpoint could allow an attacker limited ability to modify Command Centre log files. This issue affects: Gallagher Command Centre v9.10 prior to vEL9.10.1268 (MR1). | ||||
| CVE-2024-23906 | 1 Gallagher | 2 Controller 6000, Controller 7000 | 2025-07-13 | 6.1 Medium |
| Improper Neutralization of Input During Web Page Generation (CWE-79) in the Controller 6000 and Controller 7000 diagnostic webpage allows an attacker to modify Controller configuration during an authenticated Operator's session. This issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior. | ||||
| CVE-2025-35983 | 1 Gallagher | 1 Controller 7000 | 2025-07-13 | 6.5 Medium |
| Improper Certificate Validation (CWE-295) in the Controller 7000 OneLink implementation could allow an unprivileged attacker to perform a limited denial of service or perform privileged overrides during the initial configuration of the Controller, there is no risk for Controllers once they are connected. This issue affects Controller 7000: 9.30 prior to vCR9.30.250624a (distributed in 9.30.1871 (MR1)). | ||||
| CVE-2024-23317 | 1 Gallagher | 2 Controller 6000, Controller 7000 | 2025-07-12 | 6.3 Medium |
| External Control of File Name or Path (CWE-73) in the Controller 6000 and Controller 7000 allows an attacker with local access to the Controller to perform arbitrary code execution. This issue affects: 9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), 8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior. | ||||
| CVE-2024-24972 | 1 Gallagher | 2 Controller 6000, Controller 7000 | 2025-07-12 | 6.5 Medium |
| Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes. This issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior. | ||||
| CVE-2024-21815 | 1 Gallagher | 1 Command Centre | 2025-02-10 | 9.1 Critical |
| Insufficiently protected credentials (CWE-522) for third party DVR integrations to the Command Centre Server are accessible to authenticated but unprivileged users. This issue affects: Gallagher Command Centre 9.00 prior to vEL9.00.1774 (MR2), 8.90 prior to vEL8.90.1751 (MR3), 8.80 prior to vEL8.80.1526 (MR4), 8.70 prior to vEL8.70.2526 (MR6), all version of 8.60 and prior. | ||||
| CVE-2024-21838 | 1 Gallagher | 1 Command Centre | 2025-02-10 | 6.8 Medium |
| Improper neutralization of special elements in output (CWE-74) used by the email generation feature of the Command Centre Server could lead to HTML code injection in emails generated by Command Centre. This issue affects: Gallagher Command Centre 9.00 prior to vEL9.00.1774 (MR2), 8.90 prior to vEL8.90.1751 (MR3), 8.80 prior to vEL8.80.1526 (MR4), 8.70 prior to vEL8.70.2526 (MR6), all version of 8.60 and prior. | ||||
| CVE-2023-24584 | 1 Gallagher | 2 Controller 6000, Controller 6000 Firmware | 2025-01-10 | 7.5 High |
| Controller 6000 is vulnerable to a buffer overflow via the Controller diagnostic web interface upload feature. This issue affects Controller 6000: before vCR8.80.230201a, before vCR8.70.230201a, before vCR8.60.230201b, before vCR8.50.230201a, all versions of vCR8.40 and prior. | ||||
| CVE-2023-23570 | 1 Gallagher | 1 Command Centre | 2024-11-27 | 5.4 Medium |
| Client-Side enforcement of Server-Side security for the Command Centre server could be bypassed and lead to invalid configuration with undefined behavior. This issue affects: Gallagher Command Centre 8.90 prior to vEL8.90.1620 (MR2), all versions of 8.80 and prior. | ||||
| CVE-2024-22383 | 1 Gallagher | 1 Controller 7000 | 2024-11-21 | 6.2 Medium |
| Missing release of resource after effective lifetime (CWE-772) in the Controller 7000 resulted in HBUS connected T-Series readers to not automatically recover after coming under attack over the RS-485 interface, resulting in a persistent denial of service. This issue affects: All variants of the Gallagher Controller 7000 9.00 prior to vCR9.00.231204b (distributed in 9.00.1507(MR1)), 8.90 prior to vCR8.90.240209b (distributed in 8.90.1751 (MR3)), 8.80 prior to vCR8.80.240209a (distributed in 8.80.1526 (MR4)), 8.70 prior to vCR8.70.240209a (distributed in 8.70.2526 (MR6)). | ||||
| CVE-2023-6355 | 1 Gallagher | 2 Controller 7000, Controller 7000 Firmware | 2024-11-21 | 6.8 Medium |
| Incorrect selection of fuse values in the Controller 7000 platform allows an attacker to bypass some protection mechanisms to enable local debug. This issue affects: Gallagher Controller 7000 9.00 prior to vCR9.00.231204b (distributed in 9.00.1507 (MR1)), 8.90 prior to vCR8.90.231204a (distributed in 8.90.1620 (MR2)), 8.80 prior to vCR8.80.231204a (distributed in 8.80.1369 (MR3)), 8.70 prior to vCR8.70.231204a (distributed in 8.70.2375 (MR5)). | ||||
| CVE-2023-46686 | 1 Gallagher | 1 Command Centre | 2024-11-21 | 5.5 Medium |
| A reliance on untrusted inputs in a security decision could be exploited by a privileged user to configure the Gallagher Command Centre Diagnostics Service to use less secure communication protocols. This issue affects: Gallagher Diagnostics Service prior to v1.3.0 (distributed in 9.00.1507(MR1)). | ||||
| CVE-2023-41967 | 1 Gallagher | 2 Controller 6000, Controller 6000 Firmware | 2024-11-21 | 2.4 Low |
| Sensitive information uncleared after debug/power state transition in the Controller 6000 could be abused by an attacker with knowledge of the Controller's default diagnostic password and physical access to the Controller to view its configuration through the diagnostic web pages. This issue affects: Gallagher Controller 6000 8.70 prior to vCR8.70.231204a (distributed in 8.70.2375 (MR5)), v8.60 or earlier. | ||||
| CVE-2023-25074 | 1 Gallagher | 1 Command Centre | 2024-11-21 | 7.1 High |
| Improper privilege validation in Command Centre Server allows authenticated unprivileged operators to modify and view Competencies. This issue affects Command Centre: vEL8.90 prior to vEL8.90.1318 (MR1), vEL8.80 prior to vEL8.80.1192 (MR2), vEL8.70 prior to vEL8.70.2185 (MR4), vEL8.60 prior to vEL8.60.2347 (MR6), vEL8.50 prior to vEL8.50.2831 (MR8), all versions vEL8.40 and prior. | ||||